Use case · Energy monitoring

Know what every feeder consumes — and what it costs — right now.

ModbusSudo reads your existing energy meters over Modbus and the SensorLoop IoT Platform turns them into a live energy dashboard with ₹ cost, demand tracking, PF alerts and automatic reports. No more month-end surprises on the electricity bill.

app.sensorloop.in LIVE
Main Incomer · LT Panel 1
Sample data · updates every 1.5 s
ONLINE
Load
45.4kW
Power factor
0.97
Today
612kWh
Cost today
₹5,140
Live load · kWContract demand 65 kW
Phase voltage
R
231.4 V
Y
229.8 V
B
233.1 V
Alerts
  • PF below 0.90 · Feeder 3
  • Demand back to normal

This use case runs on SensorLoop products — no custom development needed.

Parameters monitored

Everything your team needs to watch

Values are read directly from your meters, sensors and controllers, labelled in plain language and shown with the right units.

Voltage (phase-wise)

R, Y, B phase and line voltages with unbalance %

Current

Phase-wise current and neutral current

Active power (kW)

Total and per-phase live load

Apparent power (kVA)

For demand and transformer loading

Reactive power (kVAr)

To size and check capacitor banks

Power factor

Live and daily average PF

Frequency

Grid and DG frequency stability

Energy (kWh / kVAh)

Hourly, daily and monthly consumption

Demand

Rolling maximum demand vs contract demand

On the dashboard

What you get with Energy Monitoring

Live load & cost

kW, kVA and PF update every few seconds. Today's and this month's kWh are converted into ₹ using your own tariff.

Demand vs contract demand

See maximum demand building up through the day and how close you are to your sanctioned contract demand.

Phase balance

R, Y, B voltage and current bars with unbalance %, so overloaded phases and failing supply are easy to spot.

Consumption analysis

Hourly, daily and monthly kWh with cost, load factor, night base-load and a 14-day hourly heatmap.

Month-end forecast

Projected units and bill for the month based on consumption so far — useful for budgeting and planning.

Reports on autopilot

Daily, weekly and monthly energy reports in PDF and Excel, sent automatically to management and accounts.
Alerts

Hear about it in seconds — not at the end of the month

Set limits per parameter and choose who gets notified. Alerts go out on WhatsApp, SMS and email with the exact value, device and time.

WhatsApp SMS Email Dashboard pop-up Escalation
  • OverloadCritical

    Feeder 2 load 182 A — above 170 A limit

  • Phase failureCritical

    Y-phase voltage dropped to 0 V at LT Panel 1

  • High demandWarning

    Demand at 92% of contract demand (60 / 65 kVA)

  • Low power factorWarning

    PF 0.86 for 15 minutes — check capacitor bank

  • Voltage out of rangeWarning

    R-phase 251 V — above 245 V limit

  • Daily summaryReport

    Yesterday: 1,284 kWh · ₹10,780 · Avg PF 0.97

AI-based energy insights

The platform analyses your data continuously and points out what deserves attention.

  • Detect abnormal consumption compared with the same hour on normal days
  • Identify peak-demand waste — which hours push your maximum demand up
  • Detect load imbalance across R, Y and B phases
  • Suggest power factor correction when PF trends downward
  • Identify idle equipment running at night, on Sundays and holidays

What connects

ModbusSudo works with the equipment you already have. Typical devices in this use case:

  • Multifunction energy meters with RS-485 Modbus (most meters from Schneider, Secure, L&T, Selec, Elmeasure and others)
  • Existing panel meters on main incomer, DG and feeders
  • CT-based submeters for machine-wise monitoring
  • ModbusSudo gateway with multiple meters on one RS-485 line
Why it matters

Built around how Indian industrial bills are calculated

Most of the avoidable cost on an HT or LT industrial bill comes from a few line items. SensorLoop puts each of them on screen while you can still do something about it.

PF penalties & incentives

Many state DISCOMs charge a penalty when average PF falls below the prescribed limit and give a rebate when it stays high. Live PF and low-PF alerts help you stay on the right side.

Contract & maximum demand

Exceeding contract demand often attracts excess-demand charges at a higher rate. Demand tracking and early warnings let you shed or shift load in time.

Time-of-Day (ToD) tariff

Where ToD tariffs apply, peak-hour units cost more. Hourly consumption analysis shows which loads can move to off-peak hours.

kVAh billing

With kVAh-based billing, poor PF directly increases billed units. Tracking kVAh alongside kWh shows the real cost of reactive power.

Lower bills
Reduced electricity cost from PF, demand and idle-load control
Minutes, not days
Faster fault detection with instant alerts
Per feeder
Improved energy efficiency with machine-wise visibility
FAQ

Energy Monitoring: common questions

Can you use the energy meters already installed in my panel?+

Yes, if they have an RS-485 (Modbus RTU) or Ethernet (Modbus TCP) port. Most digital multifunction meters do. If a meter has no communication port, we can suggest a suitable Modbus meter.

How many meters can one gateway read?+

One ModbusSudo reads several meters (slaves) on a single RS-485 line. Pricing is per number of slaves — see the pricing page.

Will the ₹ cost match my electricity bill exactly?+

The dashboard uses the tariff you set (energy rate, demand charge and so on) and gives a close estimate for daily tracking. Your DISCOM bill remains the final reference.

Can I monitor DG sets and solar as well?+

Yes. Any meter on a DG set, solar inverter or transformer that speaks Modbus can be added as its own device on the dashboard.

Want to see ModbusSudo on your own devices?

Tell us what you want to monitor. We'll suggest the right sensors and setup — and show you a live demo.