Skip to content
SENSORLOOPINDUSTRIAL IOT & TECHNOLOGY
Product · ModbusSudo

ModbusSudo Industrial IIoT Gateway

SensorLoop's own IIoT gateway. It reads any Modbus RTU or Modbus TCP device and shows the data on the SensorLoop portal — in real time, with local buffering so nothing is lost when the network drops.

MODBUS SUDO
MB-RTU● LIVE
kW48.62
PF0.97
SLV03/03
PWR
NET
TX
RX
Modbus RTU / TCP
RS-485 & Ethernet
9–36 V DC
Wide power input
WiFi · LAN · 4G · LoRa
Pick per site
Local buffering
No data gaps
Key features

Everything you need between the panel and the cloud

ModbusSudo is built for electrical panels and plant floors: it talks to the devices you already have and keeps working through power and network disturbances.

Modbus RTU & TCP

Reads RS-485 Modbus RTU devices and Modbus TCP devices on your network — energy meters, VFDs, PLCs and analysers.

Multi-device (slave) support

One gateway polls several slave devices on the same line, so a whole panel needs just one gateway.

Local data buffering

If the internet drops, readings are stored with timestamps and uploaded automatically when the link returns.

Secure data transmission

Data is encrypted between the gateway and the SensorLoop cloud. Access is controlled per customer and user.

Remote configuration

Register maps, polling intervals and settings are managed remotely — fewer site visits for changes.

Industrial-grade reliability

Wide 9–36 V DC input, OLED status display and status LEDs for quick on-site checks by your electrician.
Typical installation

Where ModbusSudo sits in your plant

Mounted inside the electrical or control panel, the gateway connects to your devices on one side and to the internet on the other.

TDS / pH sensors
Energy meters
PLC & VFD
4–20 mA sensors
ModbusSudo Gateway
Edge buffer · WiFi · LAN · 4G · LoRa
SensorLoop secure cloud
Dashboard
Alerts
Reports
STEP 01

Wire the RS-485 bus

Connect A/B terminals of each Modbus device in a daisy chain to the gateway. Each device gets a unique slave ID.

STEP 02

Power & connect

Power the gateway from a 9–36 V DC supply in the panel and connect Ethernet, WiFi, 4G or LoRa.

STEP 03

Map & go live

We map the registers you need. Values appear on your dashboard within minutes of commissioning.

Specifications

Technical overview

Need the full datasheet with dimensions, enclosure and environmental ratings? We'll send it along with wiring diagrams.

Field interface
Protocols
Modbus RTU (RS-485), Modbus TCP/IP
Devices per gateway
Multiple slave devices (multi-drop RS-485 / TCP)
Supported devices
Energy meters, VFDs, PLCs, water analysers, transmitters with Modbus output
Data points
Configurable register map per device
Connectivity
Standard
WiFi, Ethernet
Optional
4G cellular (SIM / carrier charges extra), LoRa wireless
Cloud link
Encrypted transmission to SensorLoop cloud
Reliability
Local buffering
Stores timestamped data during network loss and uploads on reconnect
Edge processing
Edge-level pre-processing before upload
Configuration
Remote configuration and updates
Hardware
Power input
9 V to 36 V DC
Display
On-board OLED status display
Indicators
Power, network, TX and RX status LEDs
Mounting & enclosure
Panel mount — contact us for the detailed datasheet
Operating environment
Industrial-grade design — contact us for the detailed datasheet
Connectivity options

One gateway, four ways to reach the cloud

Choose the link that suits each site. Mix and match across plants — all data lands in the same dashboard.

Standard

Ethernet

Plug into the plant LAN for the most stable link. Ideal when a network point is near the panel.

Standard

WiFi

Connect to an existing WiFi network without running new cables to the panel.

Optional

4G cellular

For remote pump houses, tanks and sites without internet. SIM and carrier charges extra.

Optional

LoRa

Long-range wireless link for large campuses where panels are far from the network.

What it enables

Hardware is only the start

Every ModbusSudo comes connected to the SensorLoop platform, so your data is useful from day one.

  • Real-time parameter monitoring from anywhere
  • Remote access to industrial data on web and mobile
  • Centralised dashboard for every panel and plant
  • Instant alerts on WhatsApp, SMS and email
  • Automated daily, weekly and monthly reports
Live dashboards
Instant alerts
Auto reports
Secure cloud
See it in action

TDS monitoring, live on the portal

Our showcase use case: an online TDS meter on an RO outlet talks Modbus over RS-485, ModbusSudo reads it every few seconds, and the SensorLoop IoT Platform shows each tank against BIS IS 10500 limits.

  • Live TDS, pH, EC and flow per tank
  • WhatsApp alert the moment TDS crosses the limit
  • Daily compliance % for every tank and site
app.sensorloop.in LIVE
Tank 01 · RO Outlet
Sample data · updates every 1.5 s
ONLINE
TDS
399ppm
pH
7.2
Flow
3.8m³/h
Compliance
98.6%
TDS trend · ppmBIS limit 500 ppm
Water quality band
ExcellentGoodFairPoor
Alerts
  • TDS rising · Tank 02
  • pH back in range

Designed in-house by SensorLoop

Hardware, PCB, firmware and cloud are all built by our own engineering team — the same team that takes on custom embedded projects.

Hardware PCB Firmware Cloud & appsOur services

Get the ModbusSudo datasheet

Tell us which meters or devices you use and we'll send the datasheet, wiring diagram and a quote for your panel.